Micro/Sys EPC182 - Opto-Isolated Digital Inputs and Relays on an EPIC-Footprint Card Simple Type: I/O Module

The EPC182 provides 64 lines of isolated inputs capable of handling a voltage range of 3VDC to 50VDC and provides 4kVrms isolation between the input and the digital system. There is no high-voltage inter-channel isolation between inputs. Each input can be individually pulled high or pulled low to insure a known logic level on power up. The 16 Form-C relays provide a switching capacity of 2 Amps at 30 Volts. The current states of the relays are readable and the relays will retain their states during power down or power up of the EPC182. The relays provide 1.5kVAC isolation between the high-voltage signal and the digital system as well as 250VDC isolation between relays.

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • 16 Form-C latching relays with 1.5kVAC isolation
  • 3VDC to 50VDC input range
  • 64 inputs with 4kVrms isolation
  • Relay switching capacity 2A max at 30V
  • Relays retain existing state when power is removed or applied

Specifications

    General
  • Environmental: -40 - +85°C operating, -40 - +85°C storage 5%-95% relative humidity, non-condensing
  • External Connections: Four 34-pin headers for isolated inputs. One 50-pin header for relays
  • Isolated Digital Inputs: 3VDC to 50VDC input range
  • Isolated Digital Inputs: 4kVrms isolation from logic levels to high-voltage signals
  • Isolated Digital Inputs: 64 isolated inputs
  • Isolated Digital Inputs: Input impedance = 10kohms
  • Isolated Digital Inputs: No high-voltage inter-channel isolation on inputs
  • Isolated Digital Inputs: User-selectable pull-up/pull-down resistor on each input
  • Mechanical: EPIC-footprint board size and corner
  • mounting holes: 4.53” x 6.50” x.6”
  • PC/104 Interface: 8-bit PC/104 transfers with 16-bit pass-through connector. Jumper selectable base address range from 000h to 3F0h. Occupies 16 byte-wide I/O addresses.
  • Power Requirements: +5v ±5% at 1.5Amps Max (330mA typical, no relays energized)
  • Relays: 1.5kVAC isolation from logic levels to high-voltage signal
  • Relays: 16 Form-C latching relays
  • Relays: 250V high-voltage inter-channel isolation
  • Relays: Able to read current state of the relay
  • Relays: Maximum switching capacity 2A at 30V
  • Relays: Relays retain their state when power is removed or applied

 

Applications